- Universally programmable for
- RTDs
- Thermocouples
- Resistance - sensor
- mV - sensor
- Output linear to temperature with input signal from
RTDs and Thermocouples
- Analog output 4 … 20 mA, invertible, 2 - wire design
- Signalling configurable for sensor burnout and
sensor short circuiting
- Ex class protection, intrinsically safe ATEX
Approved
- EEx ia llC T4 / T5 / T6
- EExnA
- EExd (when fitted in H70 connection head)
- EMC Conformity per
- EN 61326:1997/P1:1998/P2:2001
- NAMUR NE 21
- Galvanic isolation
- 100% Rh protection, moisture condensation
permissible
- Increased ambient temperature
- PC configurable, Windows® programme
- CE Conformity
General Description
The digital temperature transmitter TR12 range is designed
for universal industrial use.
Comprehensive configuration possibilities, for example,
type of sensor, measuring range and error signalling, high
accuracy, galvanic isolation and EMI protection characterize
these transmitters. The compact head mounting case
fits in almost any DIN connecting head.
During configuration any one of 17 input signals can be
selected. Measured temperatures are from - 200 °C up to
+ 2300 °C.
The following sensors can be connected:
- RTDs per EN60751, JIS C 1606, DIN 43 760 in 2, 3
and 4 - lead connection, the connection system used
is configurable and ensures an optimal lead wire compensation
- Thermocouples per IEC 584 , DIN 43 710 and ASTM
E988. Cold junction compensation (CJC) is built-in,
the use of an external CJC is selectable via configuration.
- Resistance-sensors up to 5 k W in 2 - , 3 - and 4 - lead
connection, configurable compensation of the connection
cable
- mV-sensors up to 800 mV
Configuration is carried out by means of a standard DOS
PC using the configuration set. With the Configuration
Software the required parameters are defined. Data to the
TR12 is down-loaded using a Communication-Interface
(Programming Unit). The bi-directional communication
enables display of the measured values on the PC.
Configuration can be effected whilst the transmitter is
mounted in the field. The Communication-Interface has an
integral isolation barrier which allows configuration whilst
the transmitter is within hazardous areas, and acts to protect
the PC. Configuration sets are available as an optional
extra. The transmitters are delivered with any customized configuration
within the given limits. |
|
|